SH15 Amorphous-alloy oil-immersed transformer
- 6 / 6.3 / 10 kV → 0.4 kV
- 30 – 2500 kVA
S13-M hermetically sealed oil-immersed distribution transformer, 30–2500 kVA, 6/6.3/10 kV to 0.4 kV, with reduced no-load loss and noise.
The S13 is a distribution transformer developed by Jiangsu Xinhong on the basis of the earlier S11 series. Through the application of new materials and new processes, the core and winding structure has been optimised and redesigned to reduce no-load loss and noise.
The noise level is on average 20% below the limits of the industry standard JB/T 10088-2016.
| Model | Rated capacity (kVA) | Vector group | HV (kV) | Tapping range | LV (kV) | No-load loss (W) | Load loss Dy (W) | Load loss Yy (W) | No-load current (%) | Short-circuit impedance (%) |
|---|---|---|---|---|---|---|---|---|---|---|
| S13-M-30 | 30 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 80 | 630 | 600 | 1.5 | 4 |
| S13-M-50 | 50 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 100 | 910 | 870 | 1.3 | 4 |
| S13-M-63 | 63 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 110 | 1090 | 1040 | 1.2 | 4 |
| S13-M-80 | 80 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 130 | 1310 | 1250 | 1.2 | 4 |
| S13-M-100 | 100 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 150 | 1580 | 1500 | 1.1 | 4 |
| S13-M-125 | 125 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 170 | 1890 | 1800 | 1.1 | 4 |
| S13-M-160 | 160 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 200 | 2310 | 2200 | 1 | 4 |
| S13-M-200 | 200 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 240 | 2730 | 2600 | 1 | 4 |
| S13-M-250 | 250 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 290 | 3200 | 3050 | 0.9 | 4 |
| S13-M-315 | 315 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 340 | 3830 | 3650 | 0.9 | 4 |
| S13-M-400 | 400 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 410 | 4520 | 4300 | 0.8 | 4 |
| S13-M-500 | 500 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 480 | 5410 | 5150 | 0.8 | 4 |
| S13-M-630 | 630 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 570 | 6200 | 6200 | 0.6 | 4.5 |
| S13-M-800 | 800 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 700 | 7500 | 7500 | 0.6 | 4.5 |
| S13-M-1000 | 1000 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 830 | 10300 | 10300 | 0.6 | 4.5 |
| S13-M-1250 | 1250 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 970 | 12000 | 12000 | 0.5 | 4.5 |
| S13-M-1600 | 1600 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 1170 | 14500 | 14500 | 0.5 | 4.5 |
| S13-M-2000 | 2000 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 1550 | 18300 | 18300 | 0.4 | 5 |
| S13-M-2500 | 2500 | Yyn0 or Dyn11 | 10 / 6.3 / 6 | ±5% or ±2×2.5% | 0.4 | 1830 | 21200 | 21200 | 0.4 | 5 |
Vector group Yyn0 or Dyn11, HV 10 / 6.3 / 6 kV, tapping range ±5% or ±2×2.5% and LV 0.4 kV apply to all 19 ratings. Short-circuit impedance: 4% for 30–500 kVA, 4.5% for 630–1600 kVA, 5% for 2000–2500 kVA. From 630 kVA upward a single load-loss value applies to both the Dy and Yy connections.
Parameters refer to standard designs at 50 Hz. Other capacities, voltage combinations, vector groups and special executions are available on request. Values may be updated without notice — please confirm in the technical offer.
Send the required capacity, voltage and quantity — we will reply with a technical and commercial offer including delivery to Uzbekistan.